  1. 1734-AENTR | Allen-Bradley. Catalog #: 1734-AENTR Best Selling. POINT I/O Dual Port Network Adaptor. Lifecycle status: ACTIVE. Learn how to avoid the risks of unauthorized and counterfeit products. Find Product Drawings. Find Firmware & Downloads. Register this Product. Add to BoM. Get Support. 1734-AENTR. Find a Distributor.

    • Important User Information
    • Preface
    • related documentation
    • Common Techniques Used in this Manual
    • Adapter Replacement
    • Empty Slots and RIUP Situations
    • Power Up a System for the First Time
    • Understand the Producer/ Consumer Model
    • Support of Rack-optimized and Direct Connections
    • Mixing Rack-optimized and Direct Connections
    • Identify Adapter
    • Mount the ArmorPOINT I/O Adapter and Base on a Wall or Panel
    • To install the ArmorPOINT I/O adapter module:
    • Wire the POINT I/O Adapter
    • Wire the ArmorPOINT I/O Adapter
    • Configuration Requirements
    • Set the Network Address for ArmorPOINT I/O Adapter
    • Save the Relation List
    • Use DHCP Software to Configure Your Adapter
    • Download the Program to the Controller
    • Configure the Adapter with Fixed IP Address
    • Recover From an Overloaded Adapter
    • 47 Set Up the Hardware
    • Work with the Diagnostics Pages
    • Use the Diagnostic Overview Page
    • Use the Network Settings Page
    • Use the Ethernet Statistics Page
    • Use the Identity Page
    • Use the Services Page
    • Configure the AB_ETH/IP Driver
    • New Product Satisfaction Return

    Solid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://www.rockwellautomation.com/literature/) describes s...

    Read this preface to familiarize yourself with the rest of the manual. It provides information concerning:

    conventions used in this manual ATTENTION: You must use series C POINT I/O modules with the adapter. Series A or B POINT I/O modules do not work with the adapter.

    The following conventions are used throughout this manual: Bulleted lists such as this one provide information, not procedural steps. Numbered lists provide sequential steps or hierarchical information. type is used for emphasis. Italic Rockwell Software products contain extensive tutorials and help screens. We recommend that you use these tutorial...

    Note that during a connection request from the controller, the chassis size setting is not communicated to the adapter. You must always set this chassis size using a separate operation. This includes situations when you are replacing an adapter. The adapter does not allow any I/O connections until it is configured with the appropriate chassis size ...

    The POINT I/O system cannot detect an empty terminal base. For this reason, there are numerous situations in which you can potentially configure a system that is unusable or one that exercises unintended control. In an attempt to address these situations, you must observe the following rules for I/O system construction and the removal and reinserti...

    When you power the I/O for the first time, the adapter must assign slot addresses to every module in the backplane. All I/O modules ship configured at the same address. When you first apply power, we expect that all but one module on the backplane exhibits a solid red Module Status LED. One by one the adapter resets these modules and addresses them...

    The I/O adapters and the applications described in this manual are compatible with the following firmware revisions and software releases. Contact Rockwell Automation if you need software or firmware upgrades to use this equipment The adapter uses the Common Industrial Protocol (CIP). CIP is the application layer protocol specified for EtherNet/IP,...

    The controller also produces data for other controllers to consume. The produced and consumed data is accessible by multiple controllers and other devices over the EtherNet/IP network. This data exchange conforms to the producer and consumer model. The Requested Packet Interval or RPI is the update rate specified for a particular piece of data on ...

    You can mix communication formats for different I/O modules communicating through the same adapter. I/O modules set up to use rack optimization communicate at the rate of the RPI configured for the adapter. I/O modules configured for direct communication communicate at their own individual RPIs and ignore the rack-optimized RPI.

    Use the figures to identify the external features of your I/O adapters.

    To mount the ArmorPOINT I/O adapter on a wall or panel, use the screw holes provided in the adapter module. IMPORTANT The ArmorPOINT I/O adapter must be mounted on a grounded metal mounting plate or other conductive surface. Refer to the drilling dimensions illustration for the ArmorPOINT I/O adapter with I/O bases to guide you in mounting the adap...

    Using a bladed screwdriver, rotate the keyswitch on the mounting base clockwise until the appropriate number for the I/O module you are installing aligns with the notch in the base. Refer to the installation instructions for each module to determine what this number must be. See Related Documentation on page i for a list of these installation instr...

    Refer to the following illustration to wire the adapter.

    Wire the EtherNet/IP and auxiliary power connectors on the adapter as shown.

    Class A Class B Class C Before you can use your adapter, you must configure its IP address, its subnet mask, and, optionally, a gateway address. You can use the Rockwell BootP utility, version 2.3 or later, to perform the configuration. You can also use a DHCP server or the network address switches to configure these parameters. ATTENTION: You must...

    Adjust the switches in front of the module Use a Dynamic Host Configuration Protocol (DHCP) server such as Rockwell Automation BootP/DHCP Retrieve the IP address from non-volatile memory The adapter reads the switches first to determine if the switches are set to a valid number. Set the network address by adjusting the three switches on the front o...

    You can save the Relation List for later use. To save the Relation List, perform the following steps: Select Save As... from the File menu. The Save As dialog appears. Select the folder where you want to save the Relation List. Enter a File name for the Relation List, for example, control system configuration, and click Save. You can leave the Save...

    DHCP (Dynamic Host Configuration Protocol) software automatically assigns IP addresses to client stations logging onto a TCP/IP network. DHCP is based on BootP and maintains some backward compatibility. The main difference is that BootP was designed for manual configuration, while DHCP allows for dynamic allocation of network addresses and configur...

    Create the example ladder program to test the I/O. Under the Main Program folder, double-click Main Routine. Enter the following ladder program using the tags previously created. Save the program. Follow this procedure to download the program you just saved to the ControlLogix controller. From the main menu, choose Communications>Who-Active. The Wh...

    To configure the adapter with a fixed IP address to prevent the adapter from ceasing to communicate with the ControlLogix controller: All controllers with I/O connections to the AENTR and/or the modules in its backplane need to be in program mode. In the Module Properties dialog, click the Port Configuration tab. Unselect the Enable DHCP box. Click...

    Each I/O connection established with the I/O adapter consumes a portion of microprocessor bandwidth. The amount of bandwidth used by a connection depends on several variables, such as the requested packet interval (RPI), number of I/O modules involved in the connection, and rate of change of the I/O. The AENTR adapter continuously monitors this ban...

    The following section describe how to set up the I/O Hardware.

    Click tabs to see the corresponding page. Click from this panel to see the corresponding page. Click Rockwell Automation at the top right to go to www.rockwellautomation.com. Click the following to see additional diagnostics web pages. Diagnostics - Diagnostic overview, Network Settings, Ethernet Statistics, I/O Connections, Diagnostic messaging Co...

    To use the Diagnostic Overview page for general diagnostics information, follow this procedure. Click Diagnostic Overview from the tab at the top of the page or panel on the left. The Diagnostic Overview page opens. From the Diagnostic Overview page, view the following: Ethernet Link Status Media Speed Half or Full Duplex Autonegotiate Status Syste...

    To use the Network Settings page for network related information, follow this procedure. Click Network Settings from the tab at the top of the page or panel on the left. This opens the Network Settings page. From the Network Settings page, view the following: Network Interface Ethernet Address (MAC) IP Address Subnet Mask Default Gateway Primary Na...

    Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned, follow these procedures.

    Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned, follow these procedures.

    Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned, follow these procedures.

    Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned, follow these procedures.

    Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned, follow these procedures.

    • 7MB
    • 112
  2. Purpose of this Manual. This manual is a reference guide for the 1734-AENTR, Series C and 1738-AENTR, Series B POINT I/O dual-port EtherNet/IP and ArmorPOINT I/O dual-port EtherNet/IP adapters, communications adapters for POINT I/O modules.

    • 7MB
    • 136
  3. prdsccdnstorage.blob.core.windows.net › techdatasheets1734-AENTR - .NET Framework

    2 feb 2019 · Automation Systems > Distributed I/O and Signal Converters > Fieldbus I/O Systems > Allen-Bradley Point I/O™ > POINT I/O™ Communication Adapters POINT I/O ENET ADAPTER DUAL PORT Catalogue No:1734-AENTR · Built-in power supply powers the I/O modules through the backplane · Up to 63 I/O modules per assembly, for up to 504

  1. Annuncio

    relativo a: allen bradley 1734-aentr